Enzymated Cleaner

Enzymated Cleaner

Regular price
$27.00
Sale price
$27.00
Regular price
Sold out
Unit price
per 

An effective multi-enzyme blend cleaner for both metallic and plastic instruments found in medical facilities 

Medigene Enzymated Cleaner is a highly effective detergent multi-enzyme blend, developed for the effective cleaning of metallic and plastic medical, surgical and dental instruments including both rigid and flexible endoscopes. 

Our proprietary blend of enzymes and specifically selected surfactants works synergistically to produce excellent results in the removal of proteins, lipids and carbohydrates, which commonly contaminate medical equipment. 

Medigene Enzymated Cleaner combines enzymes from the protease and lipase groupings of enzymes. The surfactants and all other ingredients are readily biodegradable. 

Medigene Enzymated Cleaner is effective in soft and hard water. Once diluted to the correct rate Medigene Enzymated Cleaner is near pH-neutral. 

Medigene Enzymated Cleaner is NOT a sanitiser and should be used as part of a complete cleaning system which includes autoclave disinfection. 

  • NEUTRAL PH WHEN DILUTED 
  • EXCELLENT RESULTS 
  • BIODEGRADABLE 

 

Ingredients

  • Diethanolamine <2.5% 
  • Balance comprises non hazardous ingredients. 
 
Storage
  • Store in a cool, dry area
  • Store away from foodstuffs. 
 
Product uses


  • Cleaning medical instruments 
  • Cleaning medical equipment


    Directions of use

    Medigene Enzymated Cleaner can be used in either cold or warm water (up to 45°C) for the removal of soils from general equipment. Dilute 100-to-1, with a soaking time of not less than 5 minutes. 

    For manual cleaning of Instruments: 

    • Where possible, remove excess contaminants by rinsing in cold running water. 
    • Dilute 10ml of Medigene Enzymated Cleaner per litre of water (50ml per 5 litres). Use cold/luke warm water as temperatures greater than 45°C will inhibit the enzyme action. 
    • Soak instruments for at least 5 minutes. If heavy soiling is present, longer soaking time may be required. 
    • Remove and rinse with warm tap or distilled water. 
    • Discard solution after use. 
    • After cleaning and rinsing, equipment can be disinfected/sterilised by appropriate means. 


    For ultrasonic cleaning: 

    • Fresh ready to use solution should be made daily. 
    • Dilute 10ml Medigene Enzymated Cleaner per litre of water (100ml per 10 Litre tank). Medigene Enzymated Cleaner should be added after the tank is filled, but before the transducer is turned on. 
    • Normal cycles should be followed. 
    • The solution should be changed when the degree of fouling exceeds the practical limits for the class of work involved (when it is cloudy). 
    • Caution: Due to the possibility of ultrasonic cleaners creating aerosols, it is recommended that lids or other suitable control measures are used while these devices are operating. 
    • Micro aerosols may cause an allergic reaction in some people. 


    Safety Instructions

    WARNING 

    • Read label & SDS before use. 
    • May damage organs via prolonged/repeated exposure (oral, dermal). 
    • Harmful to aquatic life with possible long lasting effects. 
    • Causes eye irritation. 
    • Causes mild skin irritation. 
    • Use within 12 months of opening. 
    • Keep out of reach of children. 
    • For external use only. 
    FIRST AID
    • If on skin, wash with soap & water. Rinse well with clean water.
    • If in eyes, rinse well with water. Remove any contact lenses. Continue rinsing for 5 minutes.
    • If inhaled, move to fresh air & rest where you can breathe comfortably.
    • If ingested, do not induce vomiting. Drink a glass of water.
    • Seek medical attention/advice if you feel unwell or any irritation persists.
    POISON INFO CENTRES:
    NEW ZEALAND 0800 764 766
    AUSTRALIA 13 1126